Insulation Calculator

Area and target R-value to required thickness and number of bags or batts packages.

Your estimate

Results update as you type. Round up when ordering.

Default R-3.2 per inch is typical for blown cellulose. Use the coverage chart on your bag for the bag count.

  • Formula checked against manufacturer specs
  • Rounded up to whole units
  • Runs in your browser

R-value basics

R-value measures resistance to heat flow; higher is better. Required thickness = target R ÷ R per inch of the material. Typical R per inch: fiberglass batts about 2.9–3.8, blown fiberglass about 2.2–2.9, blown cellulose about 3.2–3.8, closed-cell spray foam about 6–7.

Example: R-38 attic with blown cellulose at R-3.2/in: 38 ÷ 3.2 = 11.9 in deep.

What R-value do I need?

The U.S. Department of Energy/ENERGY STAR recommends about R-30 to R-60 for attics depending on climate zone (colder zones need more). Check your local energy code.

Reading the bag chart

Blown-in bags list coverage per bag for each R-value—use that number in the coverage field, because settled density varies by product. Seal attic air leaks before adding insulation; it often matters as much as the R-value.

✓ Formula reviewed and tested · Updated Oct 2026

Related calculators

FAQ

How accurate is the insulation calculator?

It uses the standard formula shown on this page and rounds bags, boxes and pieces up to whole units. Product sizes vary by brand, so confirm with the label or your supplier before you buy.

Should I buy extra material?

Yes. A 5–10% allowance covers cuts, spills and uneven surfaces; running short mid-job usually costs more than a few leftovers.

Is this calculator free?

Yes. Every PorchMath calculator is free, needs no account and runs entirely in your browser.